SEARCH NORMAS

Key words or numbers

To order by phone:
(801) 374-6214

To order by fax:
(801) 374-0634

To order by email.
or for questions:

Click here

[ Home ]
[ Up ]

Site produced and administered by
International Library Service.
Copyright 1998-2000.
All rights reserved.

Direct comments to:
International Library Service
P.O. Box 735
Provo, Utah 84603

ASME Performance Test Codes
(ASME Performance Test Codes are applicable to the determination of performance of specific, mechanical equipment which is designed to meet specified criteria for performance and operability. The codes provide requirements for instrumentation, test procedure, test environment, and interpretation of test results.)



PTC4.4-1981(R2003)
Gas Turbine Heat Recovery Steam Generators

$75.00


Reaffirmed Date: 2003

This Code provides procedures for the conduct and report of tests of heat recovery steam generators (HRSG) employed in combined cycle installations. Combined cycle, as used herein, shall be interpreted as a gas turbine exhausting into an HRSG, which may or may not be arranged for supplemental firing. This Code provides standard test procedures that will yield results having the highest level of accuracy consistent with current engineering knowledge and practice. This Code provides the methods to determine (a) efficiency, or effectiveness, at specified operating conditions; (b) capacity at specified operating conditions; (c) other related operating characteristics such as steam temperature and control range, inlet gas flow and temperature; pressure drops in combustion air, gas, steam and water circuits; quality and/or purity of steam; and air and bypass stack gas leakage. The rules and instructions given in this Code apply to HRSG units employed in combined cycle installations. Units operating with more than approximately 40 percent excess air shall be tested in accordance with the requirements of this Code. Units operating with less than approximately 20 percent excess air shall be tested in accordance with Performance Test Code PTC-4.1, Steam Generating Units. For units operating between 20 percent and 40 percent excess air, guidance as to the preferred test method can be obtained in Appendix 7.1. Orsat analysis is not required for tests performed under this Code. Testing of auxiliary equipment shall be governed by the Performance Test Code applying specifically to the auxiliary in question. This Code is not applicable to solid fuel fired units.

Published: 1981
Product Type: Print-Book
No. of pages: 81


STANDARDS QUICK FIND
A13
, A17, A18.18.1, A18.1, A90, A112, A120, AG, B1, B4, B5, B16, B17, B18 CU, B18 M, B20, B27.6, B27.7, B27.8M, B29, B30, B31, B32, B36, B40, B46, B47, B73, B89, B94, B107, BPE, BTH, CSD, HPS, HST, MFC, MH1, N278, N509, N510, NOG, NQA, NUM, OM, PALD, PCC, PTC, PVHO, QAI, QEI, QFO, QHO, QME, QMO, QRO, RA-S, RTP, SI, STS,TDP, Y14, Y32,



The latest
codes,
standards,
and related
publications
available from
ASME.


Click here
for the
Boiler & Pressure Vessel
Code